The lighting system for a given dust level mainly depends on the requirements of air handling

The high color rendering of fluorescent lamps can be well suitable for this application. In the wide color temperature range of the light source, the required color temperature can be easily selected.

Lamps for strictly required dust-free rooms: thin wire cables

In order to maintain the required environment, the air flow must be strictly controlled in the dust-free room under strict requirements. Therefore, any change of air flow should be avoided. Large areas of hidden lamps or surface cloth lamps should be avoided. The lamps must be as thin as possible, and the width shall be less than the distance between the suspended supports.

In this kind of lighting, the Jurassic teardrop lamp series with polycarbonate diffusion screen is used.

A more direct and economical method in the design of dust-free room is to select Jurassic simple 1 * 36W strip lamps with only thin wire cable frame. Although standard fluorescent lamps can be used as a glare source, this can be controlled by adding a reflector: zll in the lamp. These can improve the lighting efficiency by about 15%.

Lamps in dust-free room with medium dust degree: concealed lampsindustrial outdoor led security lights company - HOMMIIEE

When the dust-free room requires medium dust degree (1000 or higher), concealed lamps can be used. Whether closed lamps or open lamps are installed, it shall be ensured that the air passes through the filter rather than the lamps.

In order to avoid hindering the operating system, it is also important to design concisely. Attention should be paid to the careful use of correct lamps to avoid glare and ensure good lighting effect.

Standard for illuminance of industrial lighting

1. The illuminance standard value of industrial enterprise lighting shall be classified according to the following series: 0.1, 1, 2, 3, 5, 10, 15, 20, 30, 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000 and 3000lx.

2. The standard value of lighting design shall be the average illuminance value on the working surface of the production site.

3. For the standard value of illumination on the working surface, according to the specific requirements of the workplace and visual operation, the appropriate standard value shall be selected according to the high, medium and low. Generally, the middle value of the illumination range shall be adopted.

4. If one of the following conditions is met, the standard value of illumination on the working surface shall adopt the high value of illumination range:

5. If one of the following conditions is met, the standard value of illumination on the working surface shall adopt the low value of illumination range:

1. When carrying out temporary work;

2. When accuracy or speed is irrelevant.